Table 79. SCA Autosave Provisioning Menu Options

Option
Description
1
AutoSave System
2
AutoSave Only If Prov Changes
3
AutoSave Filename Prefix*
4
AutoSave Filename Suffix*
5
Max AutoSave File Instances*
6
AutoSave Time (Hour)
7
AutoSave Time (Minute)
8
AutoSave Retries
Note: These three fields collectively construct the name of the AutoSave SCA file on the TFTP server. The generated
SCA filename takes the following form (excluding parentheses):
(Prefix)_(Instance)(Suffix)
where:
is the AutoSave Filename Prefix value
Prefix
is a number between 1 and the Max AutoSave File Instances value
Instance
is the AutoSave Filename Suffix value
Suffix
Example: The prefix is
Flintville
SCA Autosave filename is
61184500L1-5L
Function
This option enables/disables the AutoSave system. Wait at
least five minutes after initial power-up to allow the chassis
and the provisioning on the SCM and modules to stabilize
before performing an AutoSave operation.
Select Enable or Disable (default).
This option instructs the SCA to perform an AutoSave only
if provisions have been changed on one or more modules.
Select Enable (default) or Disable.
This option is a 0–30 character string used to construct the
first part of the SCA AutoSave Filename.
This option is a 0–8 character string used in the AutoSave
Filename extension. If a period is required between
filename and extention, it should be part of the Suffix.
The default is
This option specifies the maximum AutoSave files to store
on the TFTP server. The instance number becomes part of
the filename.
This is a backup file rotation scheme, where the last "N"
files are always maintained on the the TFTP server.
Example: If this value is 3, the next three AutoSave files are
saved with the Instance number in the filename
incrementing
first file is overwritten. The 1–3 cycle repeats until one or
more filename values change, at which time the sequence
restarts at one.
The valid range is 1–7 instances, with a default of 1.
The values of these options combine to specify the time
when AutoSave occurs.
Example: AutoSave Time (Hour) is 3, and (Minute) is 15.
The AutoSave operation begins shortly after 03:15 A.M.
The default is 00:00 (midnight).
Configure customer OPTI-6100 systems to AutoSave at
different times, to prevent network congestion.
This option specifies the number of retries the system
performs following a failed AutoSave operation.
The valid range is 0–99, with a default of 5.
, the next AutoSave file instance is
.
Flintville_3.sca
.
.sca
,
,
. After three, this count restarts and the
1
2
3
, and the suffix is
3
.sca