Table 138. Ds1Vm Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Table 138
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS1VM module.
Provisioning Options
Equipment Provisioned State
AINS Time, Facility 1–28
AINS Timer, Facility 1–28
Loopback Timeout, Facility 1–28
Loopback Timer, Facility 1–28
Facility Provisioned State, DS1 1–28
DS1 Line Length, Facility 1–28
DS1 Line Coding, Facility 1–28
DS1 Loopback Detection, Facility 1–28
DS1 Line Identification, Line 1–28
DS1 Alarm Reporting, Facility 1–28
Mapping
PRI Clock Output to OMM
SEC Clock Output to OMM
61184500L1-5L

Table 138. DS1VM Provisioning Options

Settings
IS
OOS-MA
1 Minute to 96 Hours; 4:00 is the default
Enabled
Disabled (default)
1 Minute to 96 Hours; 2:00 is the default
Enabled
Disabled (default)
IS
OOS-MA
0–133 Feet (default)
134–266 Feet
267–399 Feet
AMI
B8ZS (default)
Disabled (default)
CSU
NIU
(enter text)
Enabled (default)
Disabled
GR-253 (default)
M13
Disabled (default)
Facility 1
Facility 2
Disabled (default)
Facility 1
Facility 2
Tributary Module Installation and Turn-Up
OOS-MA UAS (default)
OOS-MA UAS (default)
400–533 Feet
534–655 Feet
261