OPTI-6100 Installation and Turn-Up Practice
Table 139
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS1VME module.
Provisioning Options
Equipment Provisioned State
AINS Time, Facility 1–28
AINS Timer, Facility 1–28
Loopback Timeout, Facility 1–28
Loopback Timer, Facility 1–28
Facility Provisioned State, Facility 1–28
Framing, Facility 1–28
Line Length, Facility 1–28
Line Coding, Facility 1–28
Loopback Detection, Facility 1–28
Line ID, Line 1–28
Alarm Reporting, Facility 1–28
Mapping
PRI Clock Output to OMM
SEC Clock Output to OMM
264
Table 139. DS1VME Provisioning Options
Settings
♦
IS
OOS-MA
♦
1 Minute to 96 Hours; 4:00 is the default
Enabled
♦
Disabled (default)
♦
1 Minute to 96 Hours; 2:00 is the default
♦
Enabled
♦
Disabled (default)
IS
♦
OOS-MA
♦
Auto (default)
♦
♦
SLC 96
ESF
♦
0–133 Feet (default)
♦
134–266 Feet
♦
♦
267–399 Feet
♦
AMI
B8ZS (default)
♦
Disabled (default)
♦
CSU
♦
♦
NIU
(enter text)
♦
Enabled (default)
Disabled
♦
GR-253 (default)
♦
♦
M13
♦
Disabled (default)
♦
Facility 1
Facility 2
♦
Disabled (default)
♦
♦
Facility 1
♦
Facility 2
♦
OOS-MA UAS (default)
OOS-MA UAS (default)
♦
SF
♦
♦
Unframed
400–533 Feet
♦
534–655 Feet
♦
61184500L1-5L