NTP 116 — Replace an G-241W-P or I-241W-T indoor ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace a G-241W-P or I-241W-T indoor ONT.
1
Deactivate the ONT services (DLP 131). If you are using the SLID feature, this step
is not required. The ONT and the services can remain in service (IS).
2
If used, disable the Wi-Fi service using the Web GUI.
3
Power down the unit by using the on/off power switch.
4
Disconnect the POTS, Ethernet, coaxial, fiber optic cables (DLP 133), and power
cables from the ONT; see Figure
NTP 116-2
November 2013
Danger 1 — Contact the local utility company before you connect the
enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Danger 3 — If the coaxial output of the ONT is connected to the
dwelling infrastructure coaxial distribution system, ensure that the
coaxial distribution system is separately grounded. Grounding of the
dwelling coaxial infrastructure shall use Listed grounding devices and
must be installed in accordance with local Codes and Article 800 of the
National Electric Code, ANSI/NFPA 70, following the manufacturers
instructions.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
See the detailed specifications in the
data sheet
for the ONT temperature ranges for these ONTs.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
G-241W-P and I-241W-T unit
NTP 116-1
for the connector locations.
Edition 01
ONT Product Information Guide
3FE 55873 AAAA TCZZA