NTP 146 — Replace an I-021G-P or I-241G-Q indoor ONT
7
If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
8
Connect the SC/APC fiber optic cable (DLP 125).
9
Install the power supply according to manufacturer specifications.
10
Connect the power cable to the power connector.
11
If used, configure the SLID (chapter 6).
12
Verify the ONT LEDs, voltage status, and optical signal levels (DLP 127).
13
Activate and test the services (DLP 128).
14
If necessary, reset the ONT (DLP 126).
15
STOP. This procedure is complete.
NTP 146-4
November 2013
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.5 A.
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the operations and
maintenance documentation for the OLT for more details.