Edition 01
ONT Product Information Guide
NTP 161 — Replace an I-211M-K or I-211M-L indoor ONT
For an I-211M-L indoor ONT in a wall-mounted outdoor enclosure.
i
Slide the I-211M-L indoor ONT from the outdoor enclosure and remove
the unit.
ii
For the I-211M-L ONT, route the SC/APC fiber optic cable to the ONT.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
iii
Position the replacement I-211M-L indoor ONT within the outdoor
enclosure, as shown in Figure
iv
Secure the I-211M-L indoor ONT within the outdoor enclosure.
Note — Observe the following:
Do not overtighten the ONT bracket when securing the I-211M-L
indoor ONT to the outdoor enclosure. The unit can become skewed
and compromise the environmental seal of the ONT mounted in the
outdoor enclosure.
For an I-211M-L indoor ONT in a wall-mounted Just Inside enclosure.
i
Slide the I-211M-L indoor ONT from the enclosure and remove the unit.
ii
Route the SC/APC fiber optic cable as shown in Figure
NTP
161-2.