The power specifications of the SWRD are as follows:
input voltage range 12 +-2.0 V dc
input current of 0.25 A
The power can be supplied by the ONT or MDU. In the ONT PoE case, jumpers must
be configured on the EPC interface of the ONT to enable +12V power. In the MDU
case, when the video return channel is configured for the SWRD Ethernet port,
power is available.
Table
use IEEE 802.3-compliant materials.
The environmental specifications of the SWRD are as follows
operating temperature range is –40°F to 140°F (-40°C to 60°C) and to the
equivalent of 105.8°F (41°C) with solar loading
operating relative humidity is 5% to 95%, non-condensing
operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft (3962
m) above mean sea level
operating temperature can vary by 3°F (16.6°C) per minute, to the maximum and
minimum ranges
The physical specifications of the SWRD are as follows
housing dimensions: 6.78 in. wide by 1.29 in. deep by 5.77 in. high (17.45 cm by
3.38 cm by 14.66 cm)
weight: 1.5 lb (0.68 kg)
3-22
November 2013
3-11
lists the electrical specifications for the SWRD when all ports and cabling
Table 3-11 SWRD electrical specifications
Electrical specifications
Surge resistance on Ethernet ports
Surge resistance on RF ports
Forward pass band
Reverse operating frequency
Maximum length of power supply
coaxial cable
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Value
1.5 kV (1 positive, 1 negative)
1.5 kV (1 positive, 1 negative)
46 to 870 MHz
18.5 MHz
50 ft (15.24 m)
Edition 01