NTP 107 — Replace a B-2404-P business ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace a B-2404-P business ONT.
1
Deactivate the ONT services (DLP 131).
If you are using SLID, this step is not required. The ONT and the services can
remain in service (IS).
2
Disconnect the Ethernet, E1/T1, UPS, and power cables from the ONT (DLP 132).
Figure
NTP 107-2
November 2013
Danger 1 — Contact the local utility company before you connect the
B-2404-P to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the fiber optic cable.
Caution — Keep out of direct sunlight. Prolonged exposure to direct
sunlight can damage the B-2404-P.
Note — Observe the following:
The B-2404-P business ONT should be installed in accordance with
•
the applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The B-2404-P business ONT must be installed by qualified service
•
personnel.
See the detailed specifications in the
•
specifications
for the temperature ranges for this ONT.
NTP 107-1
shows the connections.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
B-2404-P detailed
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide