NTP 107 — Replace a B-2404-P business ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace a B-2404-P business ONT.
1
Deactivate the ONT services (DLP 131).
If you are using SLID, this step is not required. The ONT and the services can
remain in service (IS).
2
Disconnect the Ethernet, E1/T1, UPS, and power cables from the ONT (DLP 132).
Figure
NTP 107-2
November 2013
Danger 1 — Contact the local utility company before you connect the
B-2404-P to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the fiber optic cable.
Caution — Keep out of direct sunlight. Prolonged exposure to direct
sunlight can damage the B-2404-P.
Note — Observe the following:
The B-2404-P business ONT should be installed in accordance with
the applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The B-2404-P business ONT must be installed by qualified service
personnel.
See the detailed specifications in the
specifications
for the temperature ranges for this ONT.
NTP 107-1
shows the connections.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
B-2404-P detailed
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide