6 — ONT management using an ONT interface
Procedure 6-4 To access the CLI interface using the first Ethernet
port
1
Connect a computer or laptop to the first Ethernet port on the ONT using an
Ethernet cable.
2
Configure the IP address on the laptop Ethernet port to 192.168.4.1.
3
Perform one of the following:
a
b
4
Log in to a Telnet session:
login:login
password:password
where
login is the username for the ONT
password is the password for the ONT
The
5
STOP. This procedure is complete.
6-14
November 2013
If the ONT is not ranged, start a Telnet session and Telnet to 192.168.4.254.
telnet 192.168.4.254↵
Note — The 192.168.4.254 IP address remains open until the ONT has
been ranged. After the ONT has been ranged, the ONT no longer
accesses this IP address.
If the ONT is ranged, start a Telnet session using the IP address of the ONT.
For example:
telnet 192.168.3.10↵
Note — The CLI interface requires a specific username and password.
Contact your Alcatel-Lucent technical support representative for login
and password information.
Main menu
appears.