Alcatel-Lucent 7302 Information Manual page 577

Intelligent services access manager
Table of Contents

Advertisement

6
Connect the ground wire (DLP 147). Optional, as required.
The ground is a range of 1/2 to 5/8 inch strip length with outer jacket aligned with
the outer surface of the enclosure.
7
Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
8
Connect up to four DS1 cables to the RJ-48C ports (DLP 104).
9
Connect the B-0404G-B business ONT to a UPS.
i
ii
10
If used, configure the SLID (DLP 129).
11
If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
12
Plug the SC/APC adaptor into the fiber optic port located on the back of the ONT
unit (DLP 125).
13
Verify the ONT LEDs and voltage status (DLP 127).
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
ii
Position the replacement B-0404G-B business ONT within the outdoor
enclosure and between the ONT brackets, as shown in Figure
iii
Secure the B-0404G-B business ONT within the ONT brackets by turning
the brackets to the closed position.
Note — Observe the following:
Do not overtighten the ONT bracket when securing the B-0404G-B
business ONT to the outdoor enclosure. The unit can become skewed
and compromise the environmental seal of the ONT mounted in the
outdoor enclosure.
Install the UPS (DLP 110).
Plug the optional 8-pin Molex output power cord in to the ONT power
connector (DLP 115).
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the 7342 ISAM FTTU
Operations and Maintenance Procedures Guide using TL1 and CLI for
more details.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
NTP 104 — Replace a B-0404G-B business ONT
134
for more information about
November 2013
NTP
104-2.
NTP 104-5