Alcatel-Lucent 7302 Information Manual page 956

Intelligent services access manager
Table of Contents

Advertisement

NTP 149 — Replace an I-040G-R indoor ONT
Safety information
Read the following safety information before installing the unit.
Procedure
Use this procedure to replace an I-040G-R indoor ONT.
1
Deactivate the ONT services (DLP 131). If you are using the SLID feature, this step
is not required. The ONT and the services can remain in service (IS).
2
Disconnect the POTS, Ethernet, fiber optic (DLP 133), and power cables from the
ONT; see Figure
NTP 149-2
November 2013
Danger 1 — Contact the local utility company before you connect the
enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when handling the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedence when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
See
"I-040G-R unit data sheet"
temperature ranges for these ONTs.
NTP 149-1
for the connector locations.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
in the unit data sheet for the
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide