NTP 101 — Replace a B-0404-A
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace a B-0404-A business ONT.
1
Deactivate the ONT services (DLP 131).
If you are using SLID, this step is not required. The ONT and the services can
remain in service (IS).
2
Disconnect the Ethernet, E1/T1, UPS, and power cables from the ONT (DLP 132).
Figure
NTP 101-2
November 2013
Danger 1 — Contact the local utility company before you connect the
B-0404-A to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the fiber optic cable.
Caution — Keep out of direct sunlight. Prolonged exposure to direct
sunlight can damage the B-0404-A.
Note — Observe the following:
The B-0404-A should be installed in accordance with the applicable
•
requirements of the NEC or CEC. Local authorities and practices take
precedent when there is conflict between the local standard and the
NEC or CEC.
The B-0404-A must be installed by qualified service personnel.
•
Ensure temperature falls within tolerances as show in section 8.6.
•
NTP 101-1
shows the connections.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide