NTP 104 — Replace a B-0404G-B business ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace a B-0404G-B business ONT.
1
Deactivate the ONT services (DLP 131).
If you are using the SLID feature, this step is not required. The ONT and the
services can remain in service (IS).
2
If the B-0404G-B is mounted in an outdoor enclosure, open the access cover on the
outdoor enclosure by loosening the pin-in-hex screw.
3
Disconnect the ground wire, Ethernet, DS1, UPS, and power cables from the ONT
(DLP 132). For the location of the ports on the ONT; see Figure
NTP 104-2
November 2013
Danger 1 — Contact the local utility company before you connect the
enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning 1 — This equipment is ESD sensitive. Proper ESD protections
should be used when removing the fiber access cover of the business
ONT.
Warning 2 — The intrabuilding port(s) of the equipment or
subassembly is suitable for connection to intrabuilding or unexposed
wiring or cabling only. The intrabuilding port(s) of the equipment or
subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use
as intrabuilding interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE, Issue 5) and require isolation from the exposed OSP
cabling. The addition of Primary Protectors is not sufficient protection
in order to connect these interfaces metallically to OSP wiring.
Caution — Keep ONTs out of direct sunlight. Prolonged exposure to
direct sunlight can damage the unit.
Note — Observe the following:
The ONT should be installed in accordance with the applicable
requirements of the NEC or CEC. Local authorities and practices take
precedent when there is conflict between the local standard and the
NEC or CEC.
The ONT must be installed by qualified service personnel.
See the
"B-0404G-B unit data sheet"
ONTs.