Alcatel-Lucent 7302 Information Manual page 247

Intelligent services access manager
Table of Contents

Advertisement

ONT type (orderable part number)
Power/UPS model
Power UPS and cabling part
number information
FlexNet FMPS 48 V
(1) 48 V/150 W UPS part numbers:
150 W UPS
1AF14373AB — ANSI
customer-specific
1AF14373AD — ETSI, ANSI (power
cord included)
(2) ONT to UPS cable =
3EM17699AC (only for ETSI, ANSI)
O-821M-E (3FE51369 Ax) GPON SOMO ONT
Delta 48 V/50 W UPS
(1) 48V/50W UPS part number:
3EM23372AA
GES500W48V0081
(DMDU-4850)
(2) AC power cord, 1AB38334xxxx:
(3) ONT to UPS cable =
3EM18276AD
FlexNet FMPS 48
(1) 48V/150W UPS part numbers:
V/150 W UPS
1AF14373AB — ANSI-specific
customers
(2) ONT to UPS cable =
3EM17699AC
(17 of 17)
Notes
(1)
The list of detailed tests (for example, GR-1089i3 (ESD, EFT, RDE, CDE, RDI, and CDI), GR-1089i4 (LightningAC) and marks
(for example, FCC Class B, UL, CE Mark Class B, and K.21) are available from your Alcatel-Lucent technical support
representative.
(2)
The power supply is available only part of a kit that includes an ONT. Contact your Alcatel-Lucent technical support
representative for ordering information.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
2 — Part numbers, ordering, and deployment configuration overview
0010 - ANSI
Customer category or
country compliance tested
for
(1)
RBOC
ANSI municipality United
States, Canada
Common European Union
countries
ANSI municipality United
States, Canada
RBOC
ANSI municipality United
States, Canada
November 2013
Notes
Batteries not included with
UPS. Compliant batteries:
CSB GP1272 F2
GS Battery PE12V7.2
(ANSI GS Battery ALU
part number
1AF17581AC)
Issues with CDE objectives
on both UPS and ONT. Issues
with POTS idle channel
noise on RDI CR. Issues with
POTS idle channel noise on
CDI objective.
Battery not included with
UPS. Compliant battery
models:
BB Battery BP20-12
GS Battery PXL12180L
KungLong Batt.
WP20-12IE
ANSI battery part number:
1AF17581AB
Batteries not included with
UPS. Compliant battery
models:
CSB GP1272 F2
GS Battery PE12V7.2
(ANSI GS Battery ALU
part number
1AF17581AC)
Issues with CDE objectives
on UPS AC and DC and ONT
DC leads. Issues with POTS
idle channel noise on RDI
CR. Issues with POTS idle
channel noise on CDI
objective.