NTP 125 — Replace an I-010G-P, I-020G-P, or an I-040G-P indoor ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace an I-010G-P, I-020G-P, and I-040G-P indoor ONTs.
1
Deactivate the ONT services (DLP 131). If you are using the SLID feature, this step
is not required. The ONT and the services can remain in service (IS).
2
Disconnect the POTS, Ethernet, fiber optic (DLP 133), and power cables from the
ONT; see Figures
locations.
NTP 125-2
November 2013
Danger 1 — Contact the local utility company before you connect the
enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Danger 3 — If the coaxial output of the ONT is connected to the
dwelling infrastructure coaxial distribution system, ensure that the
coaxial distribution system is separately grounded. Grounding of the
dwelling coaxial infrastructure shall use Listed grounding devices and
must be installed in accordance with local Codes and Article 800 of the
National Electric Code, ANSI/NFPA 70, following the manufacturers
instructions.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
See
I-010G-P, I-020G-P, and I-040G-P detailed specifications
I-010G-P, I-020G-P, or I-040G-P unit data sheet
ranges for ONTs.
NTP
125-1,
NTP
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
for the temperature
125-2, and
NTP 125-3
for the connector
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide
in the

Advertisement

Table of Contents
loading

This manual is also suitable for:

73607330

Table of Contents