5 — VoIP overview
Parameter
Description
enable_reverse_pola
This parameter controls whether
rity
reverse polarity is used.
This parameter can be
configured only when the
enable_etsi parameter is set to
yes. It must be configured for
each line. When enabled:
For the originator of a call,
polarity is reversed when the call
is answered (200 OK received).
For the terminator of a call,
polarity is reversed prior to the
start of ringing.
For either the originator or
terminator, when the call ends
because BYE received, normal
polarity is resumed. For the
originator, if the user goes
on-hook, normal polarity is
resumed. For the terminator, if
the user goes on-hook, reverse
polarity continues until the
re-answer timer expires, then
normal polarity is resumed.
The default is "no". Set to "yes"
to enable reverse polarity.
All lines of I-240W-S ONT should
be configured the same. The
I-240W-S does not support
polarity reversal of terminating
calls.
enable_calling_nam
This parameter determines
e_id
whether a display name is output
to the phone set.
When the parameter is set to
'yes (default), the display name
is included as part of the caller
ID output data. When the
parameter is set to 'no', the
display name is not included as
part of the caller ID output data.
All lines of I-240W-S ONT should
be configured the same.
(22 of 30)
5-64
November 2013
Mode
1
N
Y
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Mode
Device
OMCIv2
2
support?
Y
All
No, value is
except
derived
package
from
C, D,
FTP/default
and E
line profile.
Y
All
Yes
except
package
C, D,
and E
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide
TL1 or CLI
parameters
N/A
TL1 using
CALLERID set
to 2 using
ent-profile-v
oipappservic
e
CLI using
calling-numb
er
using
configure
voice ont
voip-app-serv
ice