If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
5
Connect the fiber optic cable to the SC/UPC connector on the ONT.
6
If used, configure the SLID (DLP 129).
7
Activate and test the services (DLP 128).
8
STOP. This procedure is complete.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 134 — Replace an I-010S-P indoor or O-010S-P outdoor ONT
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.18
inches (3.0 cm) when connecting the fiber optic cable. A bend radius in
the cable that is too small can damage the optic fiber.
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the Operation and
Maintenance using TL1 or CLI guide for more details.
134
for more information about
November 2013
NTP 134-3