NTP 161 — Replace an I-211M-K or I-211M-L indoor ONT
Figure NTP 161-4: Fiber cable routing for the I-211M-L indoor ONT within the Just Inside
Fiber optic
5
Connect the ground wire (DLP 147). Optional, as required.
The ground is a range of 1/2 to 5/8 inch strip length with outer jacket aligned with
the outer surface of the enclosure.
NTP 161-8
November 2013
cable
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
iii
Position the I-211M-L indoor ONT within the Just Inside enclosure, as
shown in Figure
NTP
iv
Secure the I-211M-L indoor ONT within the Just Inside enclosure.
Note — Observe the following:
Do not overtighten the ONT bracket when securing the I-211M-L
indoor ONT to the Just Inside enclosure. The unit can become
skewed and compromise the environmental seal of the ONT mounted
in the outdoor enclosure.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
enclosure
System Status
Battery Power
Replace Battery
Auxillary Power
Silence
Alarm
Battery
Emergency Use
161-3.
Edition 01
ONT Product Information Guide
ONT
mounting
hole
Locking screw
22759
3FE 55873 AAAA TCZZA