Alcatel-Lucent 7302 Information Manual page 599

Intelligent services access manager
Table of Contents

Advertisement

10
Connect the B-2404-P to a UPS.
i
ii
iii
11
Verify the ONT LEDs, voltage status, and optical signal levels (DLP 127).
12
Activate and test the services (DLP 128).
13
STOP. This procedure is complete.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
Install the UPS according to the manufacturer instruction. Be sure to read
and follow all safety, installation, maintenance, and service instructions.
Verify that the power cable terminates with an 8-pin connector as shown in
Figure
NTP 106-3
and described in Table
Figure NTP 106-3: 8-pin connector
Table NTP 106-1: Pin assignments on the 8-pin connector
Pin #
Definition
1
Power input (+ 12V)
2
UPS status: On battery
3
UPS status: Battery missing
4
GNC / Optional frame ground
Plug the optional 8-pin Molex output power cord in to the power connector.
NTP 106 — Install a B-2404-P business ONT
NTP
106-1.
Pin 8
Pin5
Pin 4
Pin 1
Pin #
Definition
5
12 V power return
6
Alarm ground
7
UPS status: Replace battery
8
UPS status: Low battery
November 2013
21657
NTP 106-5