NTP 133 — Install an I-010S-P indoor or O-010S-P outdoor ONT

Safety information

Read the following safety information before installing the ONT.
Procedure
Use this procedure to install I-010S-P indoor and O-010S-P outdoor ONTs.
1
Prepare the cables at the site where the ONT will be installed (DLP 100). These
SFP ONTs do not require a power supply or AC/DC power cord.
2
Are any of the cables missing?
a
b
3
Locate each missing cable and route them to the ONT as per local practices.
4
Plug the SFP connector of the SFP ONT directly into the SFP cage of a residential
gateway. Figure
SC/UPC connector
NTP 133-2
November 2013
Danger — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the cables to or from the
ONT.
Caution — Keep ONTs out of direct sunlight. Prolonged exposure to
direct sunlight can damage the unit.
Note — Observe the following:
The ONT should be installed in accordance with the applicable
requirements of the NEC or CEC. Local authorities and practices take
precedent when there is conflict between the local standard and the
NEC or CEC.
The ONT must be installed by qualified personnel.
See the
I-010S-P and O-010S-P unit data sheet
ranges for ONTs.
If yes, go to step 3.
If no, go to step 4.
NTP 133-1
shows the SFP connector.
Figure NTP 133-1: I-010S-P indoor and O-010S-P outdoor ONT
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
for the temperature
SFP connector
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide
23149