4 — ONT and MDU statistics and performance monitoring
Alarm type
Interval
X/VDSL2 line
15 min
X/VDSL2
15 min
bearer/channel
X/DSL2 line xTU-C
15 min
(xDSL transceiver unit,
central office)
(3 of 4)
4-12
November 2013
Montype
Counter description
LOSS or LOS
Loss of signal seconds upstream
LOFS or LOF
Loss of frame seconds upstream
LOPS
Loss of power seconds upstream
LOLS
Loss of link seconds upstream
REINIT
Modem re-initialization events upstream
FAILINIT
Modem failed initialization events upstream
INITTIMEOUTS
Initialization time outs upstream
ES
Errored seconds upstream
SES
Severely errored seconds upstream
UAS
Unavailable seconds upstream
FCCB
Fast channel corrected blocks upstream
FCBB
Fast channel bad blocks upstream
SCCB
Slow channel corrected blocks upstream
SCBB
Slow channel bad blocks upstream
TXBLK
Count of transmitted blocks downstream (fast or slow)
RXBLK
Count of received blocks upstream (fast or slow)
CV
Code violations upstream
FECC
Forward error corrections upstream
CRC
Cyclic redundancy check
LOF or LOFS
Loss of frame seconds near-end
LOS or LOSS
Loss of signal seconds near-end
ES
Loss of errored seconds near-end
SES
Severely errored seconds near-end
UAS
Unavailable seconds near-end
LI
Count of the total number of full initializations
attempted on the line (successful and failed) during the
accumulation period.
FLI
Count of the total number of failed full initializations
during the accumulation period. A failed full
initialization occurs when showtime is not reached at
the end of the full initialization procedure.
CV
Code violations near-end
FEC
Count of forward error correction near-end.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide