General Description - Subaru Legacy 2002 Service Manual

Hide thumbs Also See for Legacy 2002:
Table of Contents

Advertisement

Starting/Charging Systems

1. General Description

A: SPECIFICATIONS
Item
Type
Model
Manufacturer
Voltage and output
Direction of rotation
Number of pinion teeth
No-load characteristics
Starter
Load characteristics
Lock characteristics
Type
Model
Manufacturer
Voltage and output
Polarity on ground side
Generator
Rotating direction
Armature connection
Output current
Regulated voltage
Battery
Type and capacity
GENERAL DESCRIPTION
S149001
S149001E49
Voltage
Current
Rotating speed
Voltage
Current
Torque
Rotating speed
Voltage
Current
Torque
SC(H6)-2
Designation
Reduction type
M001T86381
Mitsubishi Electric
12 V — 1.4 kW
Counterclockwise (when observed from pinion)
9
11 V
90 A or less
2,400 rpm or more
8 V
280 A or less
13.7 N·m (1.4 kgf-m, 10.1 ft-lb)
980 rpm or more
3 V
780 A or less
21.8 N·m (2.22 kgf-m, 16.1 ft-lb) or more
Rotating-field three-phase type
LR190-742
Mitubishi Electric
12 V — 100 A
Negative
Clockwise (when observed from pulley side.)
3-phase Y-type
1,500 rpm — 43 A or more
2,500 rpm — 76 A or more
5,000 rpm — 100 A or more
+0.3
14.5
/
V [20°C (68°F)]
−0.4
12 — 52 AH (75D23L)