8
Using the scanned registration mark for adjusting, measure
the distance of how much the registration mark for
comparison needs to be moved so both will overlap, and
record the value. As an example, in the figure above, it needs
to move in negative directions for both X and Y directions, so
both of the adjustment values will be a negative values.
9
Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.
10
Press the POSITION (
the setting value.
Set the X value measured in step 8.
11
Confirm the setting and press the [ESC] key (PREVIOUS).
SENSOR OFFSET ADJ. is selected and it will return to SENSOR
OFFSET ADJ. screen.
12
Press the [4] key (Y).
SENSOR OFFSET ADJ. Y screen is displayed.
13
Press the POSITION (
the setting value.
Set the Y value measured in step 8.
14
Confirm the setting and press the [ESC] key (PREVIOUS).
SENSOR OFFSET is selected and it will return to SENSOR OFFSET
ADJ. screen.
) keys and increase or decrease
) keys and increase or decrease
5-28
Supplement
Position of the registration mark is measured
at the center of the line.
Supplement
Setting range is -2.0 mm to +2.0 mm.
Supplement
Setting range is -2.0 mm to +2.0 mm.