Schlage PIB300 User Manual page 7

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Connector
J10/J11
(7)
J10 for
Access
Point A
J10/J11
J11 for
(8)
Access
Point B
J11 (9)
J8/J7
(1)
J8/J7
(2)
J8 for
Access
J8/J7
Point A
(3)
J7 for
Access
Point B
J8/J7
(4)
J8/J7
(5)
ACCESS CONTROL PANEL CONNECTION
PIB300/301
Access panel
signal
Request to exit
input
REQ TO EXIT
Request to
exit common
contact (GND)
+5V
5 VDC
Normally open
strike relay
contact
STRIKE
INPUT
Common strike
relay contact
Clock or
D1/CLK
data 1 output
Data or
DATA
data 0 input
GND
Signal ground
signal
PIB300/PIB301 output indicating when
the access point interior door handle is
making a request to exit.
Connect to the access control panel
request to exit input.
Connect only if the access point needs
to have request to exit function.
Output is pulled-up to 5 VDC and can
sink 50mA.
RESERVED 5 VDC power supply pin
for the RLBD, dry contact relay board.
Strike input monitors the access panel
strike relay.
Connect the strike signal to the normally
open or normally closed terminal of the
strike relay. The active signal state of
the PIB300/PIB301 is programmable
with the HHD.
Connect the ground signal to the
common terminal of the strike relay.
Connect only if the access point needs
to be unlocked (door) or raised (gate).
PIB300/PIB301 outputs used to present
card data to the ACP.
For an access point with a magnetic
reader, will present clock and data
signals to the access control panel.
For an access point with a wiegand or
proximity reader, will present Data1 and
Data0 signals to the ACP.
If initial hookup fails to operate, switch
wires at these terminals.
Output is pulled-up to 3.6 VDC and can
sink 50mA.
Common signal ground for the EXIT
REQ, DOOR STAT, TROUBLE, DATA/
D0 and CLK/D1 signals.
Description/Explanation
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pib301

Table of Contents