Schlage PIB300 User Manual page 259

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Calibrate
The Calibrate command displays the HandPunch's exposure values, allowing
you to verify these values are within normal operating parameters. The
standard operating parameters are shown in Table 8.
Row "r"
Column "c"
Exposure "e"
Status Display
The status display command allows you to enable or disable the displaying of
the following information.
When the status display is enabled, Figure 8-1 identifies each status display
field value.
-
O C O C O H L H L NN
O C O C O H L H L NN
Figure 8-1: Status Display Chart
Table 8: Normal Operating Parameters
Parameter
0 +/- 2
0 +/- 2
100 +/- 20
the status values of HandPunch inputs and outputs
the hand read score of the last user to verify on the system
ENTER ID
-
O = Circuit Open
C = Circuit Closed
Normal Range
Last Hand Read Score
Aux Out 2
Aux Out 1
* Aux Out 0
* Lock
Aux In 2
Request to Exit
Aux In 1
Door Monitor Switch
Tamper
* These status values are inactive if the
reader is in Card Reader Output Mode.
H = Output is OFF (High)
L = Output is ON (Low)
HandPunch 3000/4000 Manual
55