BSR 2000 Configuration and Management Guide
Configuring the Downstream Frequency and Modulation Rate
Follow the steps in this section to configure the downstream center frequency and
modulation rate:
1. Use the cable downstream frequency command in Interface Configuration
Note: The digital carrier frequency cannot be the same as the video carrier
frequency.
2. Use the cable downstream modulation command in Interface Configuration
6-46
Enforcing the Downstream Rate Limit
Enabling the Downstream Port
Entering a Description of the Downstream Port
mode to enter the fixed center frequency for the downstream channel:
MOT(config-if)#cable downstream 0 frequency {<91000000 -
857000000>}
where:
91000000 - 857000000 is the downstream frequency in Hertz.
mode to set the downstream digital to analog signal modulation rate:
MOT (config-if)# cable downstream 0 modulation [64 | 256]
where:
64 is 6 bits per downstream symbol Quadrature Amplitude Modulation
(QAM).
256 is 8 bits per downstream symbol Quadrature Amplitude Modulation
(QAM).
Use the no cable downstream modulation command in Interface Configuration
mode to restore the default:
MOT (config-if)# no cable downstream 0 modulation [64 | 256]
MGBI
Release 1.0
526360-001-00 Rev. B