Release 1.0

Configuring Upstream CM Registration Parameters

Configuring upstream CM registration parameters includes the following options:
Note: For any cable modem TFTP configuration files using the Upstream
Channel ID configuration Setting (TLV type 2), you must edit the configuration
file to update the channel ID TLV. Taking this action ensures that cable
modems implementing
with the upstream channel numbering convention. If your modems implement
upstream channel
configuration file to accommodate the BSR upstream channel numbering
convention will result in the cable modems being unable to complete
registration.
Follow these options to configure upstream CM registration parameters:
526360-001-00 Rev. B
Setting the Upstream Minislot Size
Setting the Upstream Channel Width
Setting the Upstream Range-backoff
Forcing a Range-response
Forcing a Range Power Override
Setting the Upstream Data-backoff
Configuring the Invited Ranging Interval
Configuring the Map Interval
override, failure to update the cable modems TFTP
Use the cable upstream minislot-size command in Interface Configuration mode
to set the upstream minislot size:
MOT(config-if)#cable upstream <NUM> minislot-size [2 | 4 | 8 | 16 | 32 |
64 | 128]
where:
NUM is the upstream port number.
Use the no cable upstream minislot-size command in Interface Configuration
mode to reset the upstream minislot size:
MOT(config-if)#no cable upstream <NUM> minislot-size [2 | 4 | 8 | 16 | 32
| 64 | 128]
upstream channel override
MGBI
Configuring the CMTS
will interoperate properly
6-75