Gathering Docsis Network Information; Determining The Enabled Docsis Cmts Module Type; Through Snmp - Motorola BSR 2000 Configuration And Management Manual

Broadband services router
Hide thumbs Also See for BSR 2000:
Table of Contents

Advertisement

BSR 2000 Configuration and Management Guide
3. Repeat Step 2 if you need to add additional intercept messages on this cable

Gathering DOCSIS Network Information

The following sections describe how to use show commands to gather network
information from the BSR:

Determining the Enabled DOCSIS CMTS Module Type

The enabled DOCSIS CMTS module type for the BSR can be determined through
SNMP or through the CLI.

Through SNMP:

The CMTS module type enabled for the BSR chassis can be determined via SNMP by
doing an SNMP Get on the following MIB object:
6-188
where:
mac is the intercept source, which is the MAC address from which traffic is
intercepted. Packets with a source or destination MAC address that matches
this address are copied and forwarded to the data collection server. Most
often, this MAC address is the user's CPE device, and not the MAC address
of the user's CM.
prefix specifies the destination IP address for the data collection server that
receives copies of the forwarded traffic.
0-65535 is the destination User Datagram Port (UDP) port number, which is
used exclusively by the data collection server. A default UDP port number is
not provided.
interface for other CPEs.
Determining the Enabled DOCSIS CMTS Module Type
Displaying Cable Interface Parameters
Displaying Downstream Parameters
Displaying Upstream Parameters
Viewing CM Information
Displaying Modulation Profiles
Displaying BPI Configuration Settings
MGBI
Release 1.0
526360-001-00 Rev. B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bsr 64000

Table of Contents