Release 1.0
The following output shows the existing upstream modulation profile reverting to its
original upstream modulation profile setting:
Using Flap Lists
Flap lists are used to collect statistics for determining CM problems on the network.
The CM flap list keeps track of the CM MAC address, up and down transitions,
registration events, missed periodic ranging packets, upstream power adjustments on
the BSR.
The following sections describe how Flap lists are used:
526360-001-00 Rev. B
[07/23-11:09:58:SPECMGR]-D-Error Rate: 0.0000 %, ErrorWord : 0,
TotalWord : 2108
[07/23-11:09:58:SPECMGR]-D-Channel Noise Power (1/10 dbmv) :
-197.
[07/23-11:10:08:SPECMGR]-D-Monitor Channel IfIndex = 7 :
[07/23-11:10:08:SPECMGR]-D-Error Rate: 0.0000 %, ErrorWord : 0,
TotalWord : 1926
[07/23-11:10:08:SPECMGR]-D-Channel Noise Power (1/10 dbmv) :
-196.
[07/23-11:10:18:SPECMGR]-D-Monitor Channel IfIndex = 7 :
[07/23-11:10:18:SPECMGR]-D-Error Rate: 0.0000 %, ErrorWord : 0,
TotalWord : 2434
[07/23-11:10:18:SPECMGR]-D-Channel Noise Power (1/10 dbmv) :
-197.
[07/23-11:10:19:SPECMGR]-N-Revert to mode profile 1 succeed for
channel ifIndex = 7 .
[07/23-11:10:28:SPECMGR]-D-Monitor Channel IfIndex = 7 :
[07/23-11:10:28:SPECMGR]-D-Error Rate: 0.1513 %, ErrorWord : 2,
TotalWord : 1322
[07/23-11:10:28:SPECMGR]-D-Channel Noise Power (1/10 dbmv) :
-197.
[07/23-11:10:38:SPECMGR]-D-Monitor Channel IfIndex = 7 :
[07/23-11:10:38:SPECMGR]-D-Error Rate: 0.0000 %, ErrorWord : 0,
TotalWord : 395
[07/23-11:10:38:SPECMGR]-D-Channel Noise Power (1/10 dbmv) :
-197.
Setting Flap List Parameters
Using Flap Lists to Troubleshoot CM Problems
Tips for Administering Flap Lists
MGBI
Configuring the CMTS
6-163