Configuring FFT

The fft setup command can be used to configure the FFT processor on the BCM3138/
BCM3140 chip set or to display the current FFT processor configuration.

Configuring the FFT Processor

Use the fft setup command, in Privileged EXEC mode, to configure the FFT
processor, as follows:
MOT#fft setup <Slot/Port> [sample {<256-2048>} mode {Tap-in} window
{blackman | blackman-harris | hamming | hanning | rectangular}]
where:

Displaying the FFT Processor Configuration

Use the fft setup <Slot/Port> command, without any additional arguments, to display
the current FFT processor configuration for a particular port on a particular CMTS
module, as follows:.
MOT#fft setup <Slot/Port>
where:
526360-001-00 Rev. B
Storing FFT Power Level Measurement Data
Displaying FFT Power Level Measurement Data
Slot is always 0 for the BSR 2000.
Port is a valid upstream port number.
sample 256-2048 is the number of samples of the power level measurement. The
default is 2048.
mode Tap-in is the RF Sentry's operational mode
window is the window coefficient to shape the output of the power level
measurement (rectangular, hamming, hanning, blackman, or
blackman-harris). The default is rectangular.
Slot is always 0 for the BSR 2000.
Port is a valid upstream port number.