Configuring Dqos Parameters; Configuring Dqos Gate T0 And T1 Timers - Motorola BSR 2000 Configuration And Management Manual

Broadband services router
Hide thumbs Also See for BSR 2000:
Table of Contents

Advertisement

Release 1.0
Figure 7-12
output:
MOT(config-if)#show packet-cable configuration dqos
Dynamic QoS Configuration
-------------------------
DQoS is enabled
T0 Timer: 30
T1 Timer: 60
Resource Request trap: disabled
Emergency trap: disabled
Figure 7-12 Output for the show packet-cable configuration dqos Command.

Configuring DQoS Parameters

Follow the procedures in these sections to configure DQoS parameters:

Configuring DQoS Gate T0 and T1 Timers

The DQoS Gate Timers have default parameter settings associated with them and they
do not have to be configured. If T0 and T1 timeouts are being counted in the show
packet-cable statistics gate command output, the network and the PDP server need
to be examined. T0 and T1 timers may need to be increased from their default values
to avoid T0 and T1 timeouts.
526360-001-00 Rev. B
displays typical show packet-cable configuration dqos command
seconds
seconds
Configuring DQoS Gate T0 and T1 Timers
Displaying Gates
Displaying Gate Statistics
The BSR considers the assigned gate ID to be invalid when the DQoS Gate Timer
T0 timer expires.
Issue the dqos t0-timer command in PacketCable Configuration mode to limit
the period of time that a gate can be allocated without the gate parameters being
configured:
MOT(config-pktcable)# dqos t0-timer <1-3600>
where:
1-3600 is the timer value in seconds. The default is 30.
MGBI
Configuring PacketCable
7-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bsr 64000

Table of Contents