76 Site planning and hardware deployment
"Cell reengineering" (page
If a cell falls into the category of a high density area, use
"High handset density deployment" (page 76)
Subdivide a cell To subdivide the area for smaller cells, divide the cell
into as many small cells as necessary to accommodate the number of
users in the area.
ATTENTION
If you install two DAPs close to each other for extra traffic density, ensure the
distance between the DAPs is always more than one meter and preferably more
than 5 meters.
Figure 33
Example of a subdivided cell
In
Figure 33 "Example of a subdivided cell" (page
handset users and cell 1C2 has 100 handset users. For example,
14 "Cell reengineering" (page 72)
If the handset users in cell 1C1 are all handset only users, one cell can
support 39 handset only users. Therefore, four cells are needed to
support 140 users (140÷39 = 3.5 cells).
If the handset users in cell 1C1 are handset and wired telephone
users, and one cell can support 83 users, two cells are needed to
support 140 handset and wired telephone users (140 ÷ 83 = 1.6 cells).
Procedure 26
High handset density deployment
Step
1
72). Subdivide high handset density areas only.
Action
Determine the number of handset users in the high-density
handset cell.
Count the number of users. Include users served by
through-the-floor coverage of this cell.
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.
to subdivide the cell.
76), cell 1C1 has 140
indicates the following:
Procedure 26