48 Site planning and hardware deployment
Procedure 6
Locating the cell center
Step
1
2
3
Action
Place the deployment tool at one critical point and then use the
deployment handset to obtain a change in audio quality. The
audio quality change determines the cell boundary contour.
Repeat step 1 at an adjacent critical point. The call center is
where the cell boundaries of both critical points meet. Mark the
cell center position on a floor plan.
Use the cell contours to locate a cell center.
Locate the cell center where the cell contours meet. Choose a
position on the floor plan that meets the following requirements:
is farthest from the critical points
provides good audio quality at the critical point,
complies with the requirements described in section
"Deployment requirements" (page 18)
is in the coverage area
Label the cell center on the floor plan with the following symbol.
xCn, where x = the floor and n = is the cell number in sequence
of the entire plan.
In
Figure 19 "Example of a cell center" (page
center.
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.
49), IC1 is a cell