Step
Action
1
Ensure that the SIP Line Gateway, call server, and DECT
system are configured and connected to the Ethernet.
2
Ensure that the DAPs are working.
3
Verify that a dial tone sounds if a handset goes off-hook. If no
dial tone sounds, the SIP DECT handset is not registered on
SIP Line Gateway. Verify that the following SIP settings are
configured properly:
For IP DECT Configurator
— ensure that the following values are configured:
Proxy IP address = SIP Line Gateway node IP address.
Proxy IP address port = SIP Line Gateway node IP
address port.
For more information, see
Settings" (page
— ensure that the following values are configured:
SIP domain = root domain (SIP Line configuration)
Realm = SIP domain in capital letters
user and password are entered correctly
use_registrar = yes
redirect=no
multiple_sip_ports=yes
For more information, see
Settings" (page 165)
For SIP Line Gateway
— ensure the SIP DECT handset is registered to the SIP
Line Gateway. To do so, issue the following command
from the SIP Line Gateway CLI: >slgSetShowAll. A list
of the SIP Lines currently registered on this SIP Line
Gateway appears.
For Call Server,
— ensure that SIP LINE is configured with the following
values:
SIP Line domain = SIP DECT domain
user agent prefix is entered
SIP port = SIP Proxy port, configured in IP DECT
Configurator
— ensure that UEXT is configured with the following values:
node id = sip line gateway node ID
sipu = SIP DECT user DN
scpw = password is entered according to settings in SIP
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.
Procedure 88 "Configuring IP
163).
Procedure 91 "Configuring SIP
Troubleshooting 243