Nortel CS 1000 Manual page 142

Sip dect fundamentals
Hide thumbs Also See for CS 1000:
Table of Contents

Advertisement

142 SIPN configuration
Table 19
LD 95: Configure CLID
Prompt
Response
REQ
NEW
TYPE
NAME
n
CUST
DN
xxxx, for example
5001
NAME
aaaaaa, for
example
Nick Johns
Enabling message waiting indication
Configure the Customer Data Block to enable MWI for IP DECT handsets.
Ensure that package 175 is enabled on the Call Server for this feature.
You can configure MWI using LD 15.
Table 20
LD 15: Enable message waiting indication
Prompt
Response
REQ
CHG
TYPE
IMS
CUST
n
...
IMS
YES
...
Table 21
LD 15: Enable Message Center
Prompt
Response
REQ
CHG
TYPE
FTR
n
CUST
...
OPT
MCI
...
Description
n = customer number
DN configured at the DAP and UEXT Key 0 at DN.
Handset user name
Description
IMS_DATA
n = customer number
Enable IMS
Description
FTR_DATA
n = customer number
Message Center included
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 02.02 30 March 2010
Copyright © 2008-2010 Nortel Networks. All Rights Reserved.