When The Start Switch Is Pushed - Kubota KX080-3 Workshop Manual

Hide thumbs Also See for KX080-3:
Table of Contents

Advertisement

WSM KX080-3 Mechanism
5A
(2)
(4)
30A
(3)
(1)
(11)
(8)
Function chart
Main key SW
Fuel supply pump start SW
Control unit (4 min. timer)
Fuel supply pump
(5)
(6)
(7)
(9)
ON
OFF
ON
OFF
4min
ON
OFF
ON
OFF
V-M-18
3-2 When the start switch is
pushed:
(1) Battery, 12 V
(2) Mini-fuse, 5 A
(3) SBF (slow blow fuse), 30 A
(4) Start switch
(5) Relay 1
(6) Mini-fuse, 5 A
(7) Relay 2
(8) Stop switch
(9) Fuel level sensor
(10)Fuel supply pump
(10)
V Electrical System