WSM KX080-3 Mechanism
D.Frost control
Function
The evaporator fin temperature is sensed. If detected too low, the compressor is interrupted to prevent
the evaporator from freezing.
a. KX121-3, 161-3
Activating temperature characteristic
Function
The evaporator fin temperature is sensed by a refrigerant-filled capillary tube. If the temperature drops
below a specified level, the pressure in the internal bellows drops too. The contact is now broken to turn
off the compressor clutch power.
(7) Contact
(8) Bellows
(9) Capillary tube
Thermostat
(7)
(9)
(8)
VI-M-24
Faston terminal 250
Evaporator fin temperature sensor
VI Air Conditioner