WSM KX080-3 Service
(2) Secondary pressure
[Ex: Measurement with the arm crowd]
1. Remove the side cover of the tank.
2. Connect a T joint to the arrow-marked point and
set the pressure gauge there.
3. Start the engine and run it at the maximum speed.
Take 2 or 3 measurements to have an exact read-
ing.
4. Hydraulic oil tempreture must be 50 ± 5°C, 122 ±
9°F.
Reference value : See specifications
1)Measurement port of secondary pilot pressure.
IV-S-40
Hydraulic system