u.SP1 and SP2 solenoid valve
1. Fitting the adaptor
Fit the adaptor in position as shown at left.
2. Adaptor tightening torque
G1/4 size
24.5~29.4N.m(2.5~3.0kgf.m)18.1~21.7ft.lbs
3. Quick-coupling adaptor
Pipe joint(QL, G1/4-8,4)
(RP812-6197D)
Make sure the hose connection is free from
detrimental scratches.
4. Fitting the bracket (valve, SP)
Fitting the valve assembly (unload)
Fitting the valve assembly(proportional)
Tightening torque
39.2~45.1N.m(4.0~4.6kgf.m)28.9~33.3ft.lbs
Tightening torque
48.1~55.9N.m(4.9~5.7kgf.m)35.4~41.2ft.lbs
Tightening torque
23.5~27.5N.m(2.4~2.8kgf.m)17.4~20.3ft.lbs
(1)Valve assembly (proportional)
(2)Bolt
(3)C/V(SP1 LOW)
(4)C/V(SP1 HIGH)
(5)Valve assembly(unload)
(6)Bolt
(7)Pipe joint (L, G1/4-G1/4)
(8)C/V(SP2 HIGH)
(9)C/V(SP2 LOW)
(10)(Unload, port B)
(11)(SP1)
(12)(Tank)
(13)Pipe joint (QL, G1/4-8.4)
(14)Pipe joint (S, G1/4-G1/4)
(15)O ring
(16)Pipe joint (QL, G1/4-8.4)
(17)Bracket (valve, SP)
(18)Bolt
(19)T pipe joint (F2)
(20)O ring
(21)Adaptor
(22)O ring
(23)Washer-fitted elbow
(24)O ring
(25)(SP2)
(26)(Tank)