Tightening The Flange (Muffler) Clamp; Ensuring The Clearance At The Pipe (Muffler) Outlet - Kubota KX080-3 Workshop Manual

Hide thumbs Also See for KX080-3:
Table of Contents

Advertisement

WSM KX080-3 Service
(1)
D
B
C
III-S-13

2.Tightening the flange (muffler) clamp

Tightening torque
3.9~5.9N.m(0.4~0.6kgf.m)28.2~42.7ft.lbs
3.Ensuring the clearance at the pipe
(muffler) outlet
Clearance: Over 25 mm(1.0inch)
(A)
(A) Front
4.Tightening sequence
* (A): Tighten up first.
Tightening torque
39.2~45.1N.m(4.0~4.6kgf.m)28.9~33.3ft.lbs
* (B): Tighten up second.
* (C): Tighten up second.
Tightening torque
48.1~55.9N.m(4.9~5.7kgf.m)35.5~41.2ft.lbs
* (D): Tighten up third.
* (E): Tighten up fourth.
(2)(3)(4)(5)
(7)
(6)
(8)
A
(9)
E
Engine
(1)Muffler assembly
(2)Cover (muffler)
(3)Bolt
(4)Plain washer
(5)Thermal insulation
(muffler cover)
(6)Flange (muffler)
(7)Face b
(8)Face c
(9)Face d

Hide quick links: