Unload Valve - Kubota KX080-3 Workshop Manual

Hide thumbs Also See for KX080-3:
Table of Contents

Advertisement

WSM KX080-3 Service
(1)
(2)(3)
(4)(5)
(6)(7)
(8)(9)
(10) (11)
(12)(13)
t.Unload valve
1. Fitting the adaptor
Fit the adaptor in position as shown at left.
2. Adaptor tightening torque
G1/4 size
24.5~29.4N.m(2.5~3.0kgf.m)18.1~21.7ft.lbs
G3/8 size
37.2~42.1N.m(3.8~4.3kgf.m)27.5~31.1ft.lbs
G1/2 size
58.8~63.7N.m(6.0~6.5kgf.m)43.4~47.0ft.lbs
3. Fitting the valve assembly (unload)
Tightening torque
48.1~55.9N.m(4.9~5.7kgf.m)35.4~41.2ft.lbs
(1)Accumulator
(2)Pipe joint (T, F2-F3)
(3)O ring
(4)Pipe joint (L, G1/4-G1/4)
(5)O ring
(6)Straight pipe joint(3-3-45)
(7)Pipe joint(L, G3/8-G1/2)
(8)Pipe joint (L, G3/8-G3/8)
(9)O ring
(10)Valve assembly (unload)
(11)Bolt
(12)Straight pipe joint
(13)O ring
IV-S-208
Hydraulic system

Hide quick links:

Advertisement

Table of Contents
loading