WSM KX080-3 Service
(1)Pump
(2)Control valve
(3)Line filter
(4)Tester
Joint B
Joint A
X Plug
IV-S-49
[Measurement]
1. Raise the engine speed to the maximum rpm.
2. Gradurally close the flowmeter's loading valve
and measure the flowrate and engine rpm at
each pressure point in the P-Q curve.
3. Take the measurements 3 times.
Determin the averages and take them as the final
ones.
*
Keep the oil temperature at 50 ± 5 °C(122 ± 9°F)
for the measurements.
Hydraulic system