Second Service Port Operation - Kubota KX080-3 Workshop Manual

Hide thumbs Also See for KX080-3:
Table of Contents

Advertisement

WSM KX080-3 Mechanism

6. Second service port operation

1. Turn the starter key to the RUN position.
2. Lower the lock lever.
3. Press the right switch (A) to send oil to the port
(1).
4. Press the left switch (B) to send oil to the port
(2).
Proportional control is not possible.
It is possible to adjust the flow volume of the
second
service
KUBOTA dealer when necessary.
Max. Flow
Volume
Theoretical
L/min.
Max. Pressure
2
MPa (kgf/cm
)
V-M-11
V Electrical System
port.
Contact
your
Second service
First service port
port
100
67
20.6
20.6
(210)
(210)
local