14. Disconnect left floor w i r e harness 2P connector
C685 (A) f r o m the right floor w i r e harness
connector C685 (B).
(C685) A
15. Check resistance between the No. 1 and No. 2
terminals of left floor wire harness 2P connector
C685. There should be an open circuit or at least
1 M Q .
LEFT FLOOR WIRE H A R N E S S 2P C O N N E C T O R C685
R E D / B L K
R E D / Y E L
T e r m i n a l side of male t e r m i n a l s
Is the resistance
as
specified?
YES — S h o r t in the right floor wire harness; replace
the right floor w i r e harness. •
N O — S h o r t in the left floor w i r e harness; replace
the left floor w i r e harness. •
24-53