Honda ACCORD HYBRID 2005 Service Manual page 2176

Hide thumbs Also See for ACCORD HYBRID 2005:
Table of Contents

Advertisement

S R S
DTC Troubleshooting (cont'd)
DTC 32-11: Short to Another Wire in Front
Passenger's Side Airbag Inflator
DTC 32-30: Descreased Resistance in Front
Passenger's Side Airbag Inflator
Special Tools Required
• SRS inflator simulator 07SAZ-TB4011A
• SRS simulator lead E 07XAZ-S1A0200
• SRS short canceller 070AZ-SAA0100
1. Erase the DTC m e m o r y (see page 24-25).
2. Turn the ignition switch ON (II), and check that the
SRS indicator comes on for about 6 seconds and
then goes off.
Does the SRS indicator
stay on, and is DTC
32-11
or 32-30
indicated?
Y E S — G o t o step 3.
IMO—Intermittent failure, system is OK at this t i m e .
Go to Troubleshooting Intermittent Failures
(see page 24-26). If another DTC is indicated, go to
the DTC Troubleshooting Index.
3. Turn the ignition switch OFF. Disconnect the
battery negative cable, and w a i t for 3 minutes.
4. Disconnect the right floor w i r e harness 2P
connector (A) f r o m the front passenger's side
airbag (B).
07XAZ-S1A0200
07SAZ-TB4011A
5. Connect the SRS inflator simulator (2 £ 2 connector)
and simulator lead E to the right floor w i r e harness.
6. Reconnect the battery negative cable.
7. Erase the DTC m e m o r y .
8. Read the DTC (see page 24-24).
Is DTC 32-11 or 32-30
indicated?
Y E S — G o t o step 9.
NO—Short to another w i r e in the front passenger's
side airbag inflator; replace the front passenger's
side airbag (see page 24-141). •
9. Turn the ignition switch OFF. Disconnect the
battery negative cable, and wait for 3 minutes.
10. Disconnect both seat belt tensioner 4P connectors
(see step 6 on page 24-23).
11. Disconnect SRS unit connector B (28P) f r o m the
SRS unit (see step 7 on page 24-23).
12. Disconnect the SRS inflator simulator f r o m the SRS
simulator lead.
13. Connect SRS short canceller (070AZ-SAA0100) to
the No. 23 and No. 24 terminals of SRS unit
connector B (28P) (see page 24-19).
14. Check resistance between the terminals of the SRS
simulator lead. There should be an open circuit or
at least 1 M Q .
RIGHT FLOOR
WIRE H A R N E S S
2P C O N N E C T O R
07XAZ-S1A0200
Is the resistance
as
specified?
YES —Faulty SRS unit or poor contact at SRS unit
connector B (28P) and the SRS unit. Check the
connection; if the connection is OK, replace the
SRS unit (see page 24-153). •
NO—Go to step 15.
24-64