Honda ACCORD HYBRID 2005 Service Manual page 2238

Hide thumbs Also See for ACCORD HYBRID 2005:
Table of Contents

Advertisement

S R S
D T C T r o u b l e s h o o t i n g ( c o n t ' d )
DTC 91-10: Internal Failure of the S R S Unit
NOTE: Before troubleshooting any of these DTCs, check
the battery/system voltage. If the voltage is low, repair
the charging system or replace the battery before
troubleshooting the SRS. If the battery/system voltage
is n o w OK, ask the customer if the battery ever w e n t
dead. A dead battery may trigger this DTC.
1. Erase the DTC m e m o r y (see page 24-25).
2. Turn the ignition switch ON (II), and check that the
SRS indicator comes on for about 6 seconds and
then goes off.
Does the SRS indicator
stay on, and is DTC 91-10
indicated?
YES—Replace the SRS Unit (see page 24-153). •
NO—Intermittent failure, system is OK at this t i m e .
Go to Troubleshooting Intermittent Failures
(see page 24-26). If another DTC is indicated, go to
the DTC Troubleshooting Index.
DTC 91-20: Short to Ground in S R S Indicator
Circuit
1. Erase the DTC m e m o r y (see page 24-25).
2. Turn the ignition switch ON (II), and check that the
SRS indicator c o m e s o n f o r about 6 seconds and
then goes off.
Does the SRS indicator
stay on, and is DTC 91-20
indicated?
Y E S — G o t o step 3.
NO—Intermittent failure, system is OK at this time.
Go to Troubleshooting Intermittent Failures
(see page 24-26). If another DTC is indicated, go to
the DTC Troubleshooting Index.
3. Turn the ignition switch OFF. Disconnect the
battery negative cable, and w a i t for 3 minutes.
4. Disconnect SRS unit connector A (28P) f r o m the
SRS unit (see step 7 on page 24-23).
5. Remove the gauge control m o d u l e (see page
22-235). Disconnect the gauge control module
connector (30P) (A) f r o m the gauge control module.
24-126