Wiring The Power Inputs - Advantech EKI-9316P Series User Manual

Industrial managed 16-port and 12-port full gigabit switch with poe/poe plus
Table of Contents

Advertisement

1.9.5 Wiring the Power Inputs

Do not disconnect modules or cabling unless the power is first switched off. The
device only supports the voltage outlined in the type plate. Do not use any other
power components except those specifically designated for the switch device.
POWER DOWN AND DISCONNECT THE POWER CORD BEFORE SERVICING
OR WIRING THE SWITCH.
There are two power inputs for normal and redundant power configurations. The power
input 2 is used for wiring a redundant power configuration. See the following for
terminal block connector views.
To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before
proceeding.
1. Loosen the screws securing terminal block to the terminal block receptor.
2. Remove the terminal block from the switch.
3. Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and loosen
the screws.
4. Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting up
power redundancy, connect PW2 in the same manner.
Figure 1-18. Terminal Receptor: Power Input Contacts
Figure 1-19. Removing a Terminal Block
H
I
ARDWARE
NSTALLATION
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eki-9312p series

Table of Contents