The following table describes the items in the previous menu.
Table 3-13. Management > Power over Ethernet > Global Configuration and
Status
Parameter
Admin Mode
Power Budget (1/10
Watts)
Power Consumption
(Watts)
Power Usage Alarm
Threshold (%)
Cumulative Power
Consumption (Kilo-
Watts/Hour)
Current Measured
(mA)
Voltage Guard
Threshold (1/10V)
Power Supply Volt-
age (V)
Temperature Guard
Threshold (Celsius)
PoE Temperature
(Celsius)
Fault Indication
Submit
Refresh
Interface Configuration and Status
Users can enable or disable the Admin Mode through the drop down menu, and configure the
Power Budget, Power Priority, and Power Pairs. To access this page, click Management
> Power over Ethernet > Interface Configuration and Status.
Click the drop-down menu to enable or disable the admin mode. The default is
Enable.
Enter a value [between 342 to 342 x (maximum of copper PoE port) to specify PSE
maximal supplying power. The unit is 0.1 watt.
Displays the power consumption of PSE's total real-time power consumption. It's
the summary of all PSE ports.
Enter a power usage alarm threshold (between 1 to 99). The default is 99.
Displays the cumulative PSE total power consumption. It's the summary of all PSE
ports. The unit is KWH (kilowatt hour).
Displays the total real-time output current of PSE. It's the summary of all PSE
ports. The unit is mA.
Enter a value (between 500 to 620) to specify the PSE over-load guard voltage.
The unit is 0.1 voltage. The default is 620.
Displays the input voltage of power supply units. The unit is voltage.
Enter a value (between 60 to 155) to specifies PSE over-heat guard temperature.
The unit is celsius. The default is 150.
Displays the PSE operation temperature. The unit is celsius.
Displays the PSE global fault indication.
None - Specifies PSE detects no error condition.


Power-Absent - Specifies absence of PSE input power.
Abnormal-Voltage - Specifies the measured PSE input voltage exceeds guard

threshold.

Over-Heat - Specifies the measured PSE temperature exceeds guard thresh-
old.

Other-Fault - Specifies PSE detects fault condition which not listed in selection.
Click Submit to update the screen. To save the values across a power cycle per-
form a system save.