Advantech EKI-9316P Series User Manual page 67

Industrial managed 16-port and 12-port full gigabit switch with poe/poe plus
Table of Contents

Advertisement

Table 3-14. Management > Power over Ethernet > Interface Configuration and
Status (Continued)
Parameter
Power Class
Power Consumption
Cumulative Power
Consumption
Current Consump-
tion
Detection Status
Fault Status
Submit
Refresh
Displays the PD power classify level.
N/A - Specifies the PSE port is not delivering power.


Class-0 - Specifies PSE port power class level-0 is selected. The maximal out-
put power in PSE side is 30 Watts.
Class-1 - Specifies PSE port power class level-1 is selected. The maximal out-

put power in PSE side is 4 Watts.

Class-2 - Specifies PSE port power class level-2 is selected. The maximal out-
put power in PSE side is 7 Watts.
Class-3 - Specifies PSE port power class level-3 is selected. The maximal out-

put power in PSE side is 15.4 Watts.

Class-4 - Specifies PSE port power class level-4 is selected. The maximal out-
put power in PSE side is 30 Watts.
Displays the power consumption of PSE port. The unit is watt.
Displays the power consumption summary of PSE port. The unit is KWH (kilowatt
hour).
Displays the current consumption summary of PSE port. The unit is mA.
Displays the operation status of PSE port.

Disabled - Specifies PSE port is not delivering power.
Searching - Specifies PSE port is trying to detect the connection of PD.

Delivering-Power - Specifies PSE port is delivering power to PD.


Test - Specifies PSE port IS under test.

Fault - Specifies PSE port operation fault defined in IEEE 802.3af and 802.3at.
Other Fault - Specifies PSE port operation fault other than those defined in

IEEE 802.3af and 802.3at.
Displays the fault indication of PSE port.
None - Specifies PSE port detects no error condition.

Short-Circuit - Specifies PSE port detects short circuit in PD loop.


Over-Load - Specifies PSE port detects lover-load in PD loop.

Power-Denied - Specifies PSE port denies PD power class request.
Startup-Failure - Specifies PSE port operation fault defined in IEEE 802.3af and

802.3at.

Other-Fault - Specifies PSE port fault other than those defined in IEEE 802.3af
and 802.3at.
Click Submit to update the screen. To save the values across a power cycle per-
form a system save.
Click Refresh to update the screen.
M
ANAGEMENT
Description
I
NTERFACE
55