Table 3-58. Management > LLDP > LLDP-MED > Remote Device Information (Continued)
Parameter
Extended PoE PD
Refresh

3.3.16 TACACS+

Configuration
The Configuration page allows users to configure key string and connection timeout settings
for TACACS+. To access this page, click Management > TACACS+ > Configuration.
The following table describes the items in the previous menu.
Table 3-59. Management > TACACS+ > Configuration
Parameter
Key String
Apply
Connection Timeout
Submit
Displays extended PD TLV is received in LLDP frame on this port.

Required - Specifies the remote port's PD power requirement.

Source - Specifies the remote port's PD power source.
Priority - Specifies the remote port's PD power priority.

Refresh the data on the screen with the present state of the data in the switch.
Figure 3-61. Management > TACACS+ > Configuration
Enter the authentication and encryption key for TACACS+ communications
between the device and the TACACS+ server. The valid range is 0-128 characters.
The key must match the key configured on the TACACS+ server.
Click Apply to enter the key in the Key String field. If the checkbox is not checked,
you will not be able to enter the key. By default its unchecked.
Enter the maximum number of seconds allowed to establish a TCP connection
between the device and the TACACS+ server. The default value is 5 seconds. The
valid range is 1 to 30.
Click Submit to update the switch with the values on the screen. If you want the
switch to retain the new values across a power cycle you must perform a save.